New York Bids > Bid Detail

6115--PORTABLE 500KW DIESEL GENERATOR

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • 61 - Electric Wire, and Power and Distribution Equipment
Opps ID: NBD00159392385560601
Posted Date: Apr 26, 2023
Due Date: May 3, 2023
Solicitation No: 36C24223Q0421
Source: https://sam.gov/opp/3a1ce89447...
Follow
6115--PORTABLE 500KW DIESEL GENERATOR
Active
Contract Opportunity
Notice ID
36C24223Q0421
Related Notice
36C24223Q0421
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Apr 26, 2023 12:10 pm EDT
  • Original Date Offers Due: May 03, 2023 03:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Aug 01, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: 6115 - GENERATORS AND GENERATOR SETS, ELECTRICAL
  • NAICS Code:
    • 335312 - Motor and Generator Manufacturing
  • Place of Performance:
    Engineering Services Montrose VA Medical Center Montrose , NY 10548
    USA
Description
This is a COMBINED SYNOPSIS/SOLICITATION NOTICE for

Portable 500 kW Diesel Generator

Responses to this Combined Synopsis/Solicitation must be in writing and submitted on the attached Request for Quotation (Form SF1449).

100% SDVOSB set-aside.

NAICS Code: 335312; size standard: 1,250 employees; PSC: 6115

Responses to this notice shall include the following: (a) company name  b) address (c) point of contact (d) phone, fax, and email (e) SAM UEI (f) Cage Code (g) Tax ID Number (h) and must  provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor and provide the commodities described within the Request For Quotation. Â

VA Hudson Valley Healthcare System at Montrose VA Medical Center, Engineering Service, is seeking to purchase a Portable 500kW Diesel Generator.

Portable 500 kW Diesel Generator

Objective:

This generator will meet, at a minimum, the following physical and performance characteristics:

One (1) new diesel fueled Standby Generator set rated at 500 KW, variable voltage, (208/240/480), 60 HZ, 3 phase, 0.8 power factor at 1800 rpm.
Cam lock and busbar distribution panel
Generator has a minimum of (2) 120 V GFCIs and (3) 50 amp 240 volt
Generator set in containerized module with sound attenuated air intake louvers and insulated interior walls and ceilings with minimum 4 of acoustic paneling.
Trailer has two-axle, air-ride chassis with anti-lock brake system and shall have an overall width of no more than 8 - 6 and an overall height with the mounted generator set not to exceed 10 -3 It shall be towable using a standard ball hitch.
Sound attenuated container with minimum 76dB(A) at 25 feet per SAE J1074 measured at 75% prime load.
110% spill containment of onboard engine fluids and variable speed cooling fan for reduced fuel consumption and reduced sound at partial loads.
Shore power connection via distribution block connections for jacket water heater, battery charger, space heaters, generator condensate heaters and internal duplex service receptacle.
Generator set mounted controller with automatic start/stop with cooldown timer and manual and automatic paralleling capability. Genset equipped with hardware to provide two-way communication for remote control and equipment monitoring via cellular network.
Fuel/Emissions strategy to meet US EPA Tier 4 Final emission standards and CARB certified for non-road mobile application.
Engine to have double-wall fuel tank, UL 142 listed with leak detection sensor and complies with capacity of 24-hour runtime @ 75% prime, internal and external fuel fill.
Engine equipped with 25-gal plastic Diesel Exhaust Fluid (DEF) tank with integrated pump, level sensor to display the DEF level in control panel and electrically heated lines from DEF tank to CEM.
Clean Emissions Modules (CEM) comes with integrated CRS, DOC, DPF, and SCR and is located in separate compartment.
UL listed 208/240V, 20 amp battery charger, shock-mounted and enclosed in dust-proof housing. Lube system consists of pump, integral oil cooler, lube oil, filter, filler and dipstick, and oil sampling valve.
Cooling system with vertically mounted radiator with vertical air discharge from the container to provide 47o C ambient capability at prime rating and 500m.
Suppler shall deliver, set up and demonstrate full acceptable operational performance prior to acceptance by COR/POC. This shall include documented on-site load bank test and shall include demonstration of the emergency stop capability.
Supplier shall provide (2) O & M manuals and a minimum of 1 hr of training to campus electrical staff and mechanics.
All offers must be submitted using the attached RFQ along with any other relevant information as per FAR 52.212-2 Evaluation Section E - page 40.
The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Combined Synopsis/Solicitation. This notice shall not be construed as a commitment by the Government to award a contract, nor does it restrict the Government to a particular acquisition approach.
Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Small Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. Requests for information and resultant responses shall be submitted directly to the contracting officer, Paul Speedling at Paul.Speedling@va.gov. NO TELEPHONE CALLS WILL BE ACCEPTED.
All submissions should be received no later than 15:00 EST on May 3, 2023.
Attachments/Links
Contact Information
Contracting Office Address
  • 113 HOLLAND AVE
  • ALBANY , NY 12208
  • USA
Primary Point of Contact
Secondary Point of Contact


History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >